Specialty Cryocoolers

SHI’s Specialty Cryocoolers encompass Gifford-McMahon, Joule-Thomson, Stirling and Pulse Tube technologies in temperatures from 4K to 77K.

In addition to our standard 4K, 10K and Pulse Tube Cryocoolers, SHI Cryogenics Group offers several cryocooler models designed for specialty research applications. These models include a 6.5K Gifford-McMahon Cryocooler and several single-stage Cryocoolers. Like other Cryocooler products, all Specialty Cryocoolers are backed by SHI’s worldwide sales, service and support network.

CH-204-N 6.5K Cryocooler Series

Standard scope of Supply

  • CH-204-N Cold Head
  • Zephyr®, HC-4E1, HC-8E4 or F-70L/H Compressor
  • 3 m (10 ft.) Helium Gas Lines
  • 3.5 m (11 ft.) Cold Head Cable
  • Tool Kit

Specifications

Specifications
Power Supply 50 Hz 60 Hz
2nd Stage Capacity 2.5 W @ ≤ 10 K 3.0 W @ ≤ 10 K
1st Stage Capacity -
Maximum 2nd Stage Capacity
(No 1st Stage Load)
2.5 W @ ≤ 10 K 3.0 W @ ≤ 10 K
Minimum Temperature1 6.5 K
Cooldown Time to 20 K1 40 Minutes 35 Minutes
Weight 7.8 kg (17.2 lbs.)
Maintenance 13,000 Hours
  • 1.Lowest temperature and cooldown time are for reference only. (Dependent upon ambient temperature, cooling water temperature, etc.)

Specifications subject to change without notice.

RDK-408S2 10K Cryocooler Series

Standard scope of Supply

  • RDK-408S2 Cold Head
  • CSA-71A, F-50L/H CNA-61 or FA-70L/H Compressor
  • 6 m (20 ft.) Helium Gas Lines [10 m (33 ft.) with CNA-61C/D Compressor]
  • 6 m (20 ft.) Cold Head Cable [10 m (33 ft.) with CNA-61C/D Compressor]
  • Tool Kit

Specifications

Specifications
Power Supply 50 Hz 60 Hz
2nd Stage Capacity 5.4 W @ 10 K 6.3 W @ 10 K
1st Stage Capacity 35 W @ 45 K 40 W @ 45 K
Minimum Temperature1 < 7 K
Cooldown Time to 10 K1 < 60 Minutes
Weight 17.2 kg (37.9 lbs.)
Maintenance 10,000 Hours
  • 1.Lowest temperature and cooldown time are for reference only. (Dependent upon ambient temperature, cooling water temperature, etc.)

Specifications subject to change without notice.

RDK-400B 40K Cryocooler Series

Standard scope of Supply

  • RDK-400B Cold Head
  • CSA-71A, F-50L/H or CNA-61C/D Compressor
  • 20 m (66 ft.) Helium Gas Lines or 6 m (20 ft.) Helium Gas Lines with Buffer Tank
  • 6 m (20 ft.) Cold Head Cable [10 m (33 ft.) with CNA-61C/D Compressor]
  • Tool Kit

Specifications

Specifications
Power Supply 50 Hz 60 Hz
1st Stage Capacity 54 W @ 40 K 70 W @ 40 K
Minimum Temperature1 < 25 K
Cooldown Time to 40 K1 30 Minutes
Weight 16.0 kg (35.3 lbs.)
Maintenance 10,000 Hours
  • 1.Lowest temperature and cooldown time are for reference only. (Dependent upon ambient temperature, cooling water temperature, etc.)

Specifications subject to change without notice.

RDK-500B 20K Cryocooler Series

Standard scope of Supply

  • RDK-500B Cold Head
  • F-70LP/H Compressor
  • 20 m (66 ft.) Helium Gas Lines
  • 20 m (66 ft.) Cold Head Cable
  • Tool Kit

Specifications

Specifications
Power Supply 50 Hz 60 Hz
1st Stage Capacity 40 W @ 20 K / 80 W @ 30 K 50 W @ 20 K / 95 W @ 30 K
Minimum Temperature1 < 14 K
Cooldown Time to 40 K1 70 Minutes
Weight 25.0 kg (55.1 lbs.)
Maintenance 8,760 Hours
  • 1.Lowest temperature and cooldown time are for reference only. (Dependent upon ambient temperature, cooling water temperature, etc.)

Specifications subject to change without notice.

RD-125D 77K Cryocooler Series

Standard scope of Supply

  • RD-125D Cold Head
  • CNA-11B/C Compressor
  • 5 m (16.4 ft.) Helium Gas Lines
  • 6 m (19.7 ft.) Cold Head Cable
  • Tool Kit

Specifications

Specifications
Power Supply 50 Hz 60 Hz
1st Stage Capacity 30 W @ 77 K 30 W @ 77 K
Minimum Temperature1 < 30 K
Weight 15 kg (33 lbs.)
Maintenance 10,000 Hours
  • 1.Lowest temperature and cooldown time are for reference only. (Dependent upon ambient temperature, cooling water temperature, etc.)

Specifications subject to change without notice.

CH-104 77K Cryocooler Series

Standard scope of Supply

  • CH-104 Cold Head
  • Zephyr®, HC-4E1, HC-8E4 or F-70L/H Compressor
  • 3 m (10 ft.) Helium Gas Lines
  • 3.5 m (11 ft.) Cold Head Cable
  • Tool Kit

Specifications

Specifications
Power Supply 50 Hz 60 Hz
1st Stage Capacity 34 W @ 77 K 42 W @ 77 K
Minimum Temperature1 < 25 K
Cooldown Time to 77 K1 40 Minutes 30 Minutes
Weight 7.9 kg (17.5 lbs.)
Maintenance 13,000 Hours
  • 1.Lowest temperature and cooldown time are for reference only. (Dependent upon ambient temperature, cooling water temperature, etc.)

Specifications subject to change without notice.

CH-110 77K Cryocooler Series

Standard scope of Supply

  • CH-110 Cold Head
  • Zephyr®, FA-70L/H, HC-4E1, HC-8E4 or F-70L/H Compressor
  • 3 m (10 ft.) Helium Gas Lines
  • 3.5 m (11 ft.) Cold Head Cable
  • Tool Kit

Specifications

Specifications
Power Supply 50 Hz 60 Hz
1st Stage Capacity1 175 W @ 77 K 200 W @ 77 K
Minimum Temperature2 < 25 K
Cooldown Time to 77 K2 35 Minutes 30 Minutes
Weight 13.7 kg (30.2 lbs.)
Maintenance 13,000 Hours
  • 1.Low temperature version available. Reduced capacities when operated with Zephyr®, HC-4E1 or HC-8E4 Compressors.
  • 2.Lowest temperature and cooldown time are for reference only. (Dependent upon ambient temperature, cooling water temperature, etc.)

Specifications subject to change without notice.